Community Development Block Grant Disaster Recovery (CDBG-DR) Rebuild Florida General Infrastructure Repair Program

Cottondale Active Projects

Community Development Block Grant Disaster Recovery (CDBG-DR/HR) Program

Recognizing this, Congress appropriated, and the U.S. Department of Housing and Urban Development (HUD) allocated funding to support long-term recovery efforts following Hurricane Michael through Florida Commerce’s (FC) Community Development Block Grant Disaster Recovery (CDBG-DR) Program.

 

Community Development Block Grant Disaster Recovery (CDBG-HR)

Caney Stormwater Pond Drainage Project

Florida Commerce Agreement Number M0019

 

The City of Cottondale has been awarded Four Million Three Hundred Forty-Seven Thousand Three Hundred Fifty-One Dollars and Zero Cents ($4,347,351.00) in CDBG-DR funds for the Caney Pond Drainage project. Many of the residential properties and streets in the Caney Pond Drainage Basin Service Area flooded during Hurricane Michael due to inadequate storm drainage in the area. The flooding of Caney Pond has resulted in roads being impassable and citizens not being able to return to or leave their homes. This has started to occur even in minor rain events. Without these improvements
these events will continue to hinder the lives of citizens within the service area.

The project includes:
1. Expanding the capacity of the Caney Stormwater Pond by deepening the pond.
2. The installation of stormwater piping to carry the stormwater collected in the Caney Stormwater
Pond Drainage Basin into Caney Pond.
3. The expansion of a discharge channel to carry the excess stormwater from Caney Pond into the
DOT Stormwater Collection System along Highway 231.

The specific location of this project will be: The Caney Pond basin, which is surrounded by Broad Street to the north, Elliot Drive to the east, Gilbert Lane to the south and Caney Landing Road to the west.

Community Development Block Grant Disaster Recovery (CDBG-DR)

Hometown Revitalization Project

Florida Commerce Agreement Number M0042

The City of Cottondale was awarded a nearly $1.7 million CDBG-DR grant from the FloridaCommerce to revitalize the commercial corridor along Highway 231 that runs through the center of the community. The proposed scope of work includes:

  • Proposed acquisition and demolition of two shopping plazas built in the 1930s that stand vacant and beyond repair.
  • Proposed acquisition and demolition of a commercially zoned property that includes an old fruit stand and significantly damaged house.
  • Proposed acquisition and rehabilitation of a former restaurant facility that has been vacant since Hurricane Michael.
  • The repair and resurfacing of a public parking lot in Downtown Cottondale.

Community Development Block Grant Disaster Recovery (CDBG-DR)

Northwest Sanitary Sewer Project

Florida Commerce Agreement Number M0165

The City of Cottondale has been awarded One Million Four Hundred Ninety-Nine Two Hundred and Twenty-Eight Dollars and Zero Cents ($1,499,228.00) for the Northwest Sanitary Sewer Lines Project. During Hurricane Michael, the system’s sewer lines and manholes suffered direct damage and in combination with their age, resulted in severe inflow and infiltration. The large amount of rainfall saturated the ground surrounding these pipes resulting in joint damage and lining degradation, causing sand and debris to leak into the system and wastewater/sewage to leak out. One lift station in the area was forced to far exceed its pumping capacity, due to the excessive rainfall and presence of sand and other debris, and now has been prematurely worn out.

The City of Cottondale intends to replace sewer lines, replace sanitary sewer manholes, line and rehabilitate sanitary sewer lines, line sanitary manhole covers, and replace paving. The City will also begin and finish rehabilitation on the damaged lift station and harden the 79.17% Low-Moderate Income service area surrounding the station by installing a new emergency electrical generator. This Community Development Block Grant will be the sole source of funding.

Community Development Block Grant Disaster Recovery (CDBG-DR)

Southeast Sanitary Sewer Project

Florida Commerce Agreement Number M0170

The City of Cottondale has been awarded Eight Hundred Ninety-Five Thousand Four Hundred Fourteen Dollars and Zero Cents ($895,414.00) for the Southeast Sanitary Sewer Lines Project. During Hurricane Michael, the system’s sewer lines and manholes suffered direct damage and in combination with their age, resulted in severe inflow and infiltration. The large amount of rainfall saturated the ground surrounding these pipes resulting in joint damage and lining degradation, causing sand and debris to leak into the system and wastewater/sewage to leak out. One lift station in the area was forced to far exceed its pumping capacity, due to the excessive rainfall and presence of sand and other debris, and now has been prematurely worn out.

The City of Cottondale intends to replace sewer lines, replace sanitary sewer manholes, and replace paving. The City will also begin and finish rehabilitation on the damaged lift station and harden the 70% Low-Moderate Income service area surrounding the station by installing a new emergency electrical generator. This Community Development Block Grant will be the sole source of funding.

Community Development Block Grant Disaster Recovery (CDBG-DR)

Match Sprayfield Generator Project (Match to HMGP 4399-095-R)

Florida Commerce Agreement Number M0158

The purpose of this project is to provide backup power to Sprayfield Pump Station located in Cottondale.

The project will provide protection by purchasing and installing a 125kW diesel generator or the adequate size determined by the vendor and/or electrical engineer during the bid process, to appropriately support the critical utility. The generator shall include a 400-gallon tank and a missile impact enclosure. The project also includes constructing a concrete pad, installing an automatic transfer switch (ATS), and electrical connections. The Sprayfield Pump Station is in charge of disposing the treated effluent from the wastewater treatment plant and keeping the holding pond within its normal range. The project shall allow the city to maintain the identified critical utility operations and continue to serve the community during future power outages.

Project locations: 30.779970, -85.359062

Community Development Block Grant Disaster Recovery (CDBG-DR)

Match Critical Facilities Project (Match to HMGP 4399-143-R)

Florida Commerce Agreement Number M0159

The purpose of this project is to provide backup power to three critical facility buildings located in Cottondale.

The project will provide protection by purchasing and installing three 40kW permanent generators, or generators of an adequate size determined by the vendor and/or electrical engineer during the bidding process, so that the critical facilities can continue operations in the case of a power outage. Each generator shall be installed with an automated transfer switch (ATS). The generators are to be powered by diesel fuel and each shall have its own dedicated, above ground fuel tank.

Project locations:

ID# Station kW Coordinates
1. Public Works 40kW 30.798050, -85.377807
2. Fire Station 40kW 30.795666, -85.375476
3. Police Station 40kW 30.796093, -85.375109

Community Development Block Grant Disaster Recovery (CDBG-DR)

Match Five Lift Stations Generators Project (Match to HMGP 4399-143-R)

Florida Commerce Agreement Number M0158

The purpose of this project is to provide backup power to five (5) wastewater lift stations located within Cottondale, Florida. Installation of five (5) 38kW permanent generators, one at each site, or generators of an adequate size determined by the vendor and/or electrical engineer during the bidding process, to power five (5) wastewater lift stations in the event of an outage. These lift stations are critical to the city to prevent sanitary sewer overflow. The generators shall be installed with all accessories necessary for their operation.

The generators shall be protected against a 500-year flood event by implementing specific activities or by locating the generators outside the Special Flood Hazard Area and shall be protected against wind with Federal, State, and Local Rules and Regulations.

ID# Lift Station # kW Coordinates
1. Lift Station 1 38kW 30.809506, -85.380535
2. Lift Station 2 38kW 30.795738, -85.381180
3. Lift Station 3 38kW 30.795006, -85.369967
4. Lift Station 4 38kW 30.810781, -85.376748
5. Lift Station 5 38kW 30.796210, -85.368987

CDBG-MIT Active Projects